We are pleased to quote on 2014 Custom Vac CV16 Cube Combination Vacuum/Wash System, EQ# 000000029, with the following specifications:
QUANTITY One
DESIGN: Tank designed and constructed in compliance with TC407/412 CSA B620-03
Debris Tank ( 2640 Imp Gal +3% Outage ): 78” Diameter x 12’ Lg 78” x 5/16” Heads 78” x 5/16” Shells Three reinforcement rings Three Rollover Bars Reinforcing pads on all tank attachments 8” Primary internal shutoff, SS float ball and rubber seat /cage assembly with 6” flanged outlet. 6” Heated tank isolation valve, with air control switch at operation 6” Plumbing 6” Composite loop hose c/w vic clamps Pressure Vessel Hydrotested to 40 PSI Full Opening Hydraulic Lift Rear Door c/w 6 pinwheel door locks 6” Load Valve , with internal 6” sandpipe D/S 4” Load Valve, P//S 6” Discharge Valve ,– Bottom Center of Rear Door All rear valves heated and equipped with air/open, spring/close actuators , flipper style switches ,Aluminum Camlocks and Caps Recessed Stainless Steel Liquid Level Indicator, indicator with grab handle - D/S 6” Cyclone with Clean-Out Door & 2” Brass Heated Drain 3” x 30 PSI pressure relief vent 2” Pressure Relief Valve in lower Vac/Pressure Piping
Y:\General Info-VTC\EQUIPMENT IN STOCK\STOCK\CUSTOM VAC\CV16 COMBO\EQ #000000029 - 2014 CV16 Combo -- WS\EQ #000000029-2014 CV16 Combo -- WS.doc
2
Water Compartment 4 Cubes (880 Imp Gal ): 20” Manway Stainless Steel Liquid Level Indicator ,indicator with Long Style grab handle P/S 2” Heated Fill Port c/w Riser/Vent Pipe 2”Heated Drain Valve c/w air actuated valve. Switch control at operator station. 2” Heated hard piped supply line, Direct connection through wash cabinet to wash pump 2” Heated Vacuum Changeover Valve & Air Control switch at Operator Station
Robuschi RB DV 85 PD Blower High Efficiency Tri-Lobe Design 1600 CFM Free Air Rating 27” Hg Maximum Vacuum Oil Free Operation (Except Sealed Reservoirs) Blower Clearance & Timing Inspection Prior to Installation by Hibon (Custom Vac) Certified Technicians 6” Four-Way Divertor Valve (Vacuum to Pressure Modes) 6” Double Door Check Valve (To Prevent Blower Back Spin) 16” Dia. x 20 Micron Rating (Washable) Prestage Blower Filter – Hibon Approved Design High Torque/High Temp Blower Drive Coupling with Flexible Insert One Exhaust Silencer, One Intake Silence
Power Take-Off System: 8-Bolt Air Shift P.T.O. (Greaseable Shaft Seal) Air Shift Controls & Hour Meters in Control Box by Driver’s Seat
Hydraulic System ( Linde Closed Loop Design ): Closed loop hydraulic motor for blower and triplex Closed loop hydraulic pump for blower and triplex Single pump for auxiliary functions Spool type valve bank Rear deck controls for rear door Variable Speed Joystick Control for Blower Wash pump and Hydraulic reel controls are mounted inside wash cabinet 90 Imperial Gallon Hydraulic Oil Reservoir (Cleaned, Purged & Air Tested Prior to Installation) c/w Intank (10 Micron) Filter, Temperature & Level Indicators Global Hydraulic Vibrator with Flow Control Valve 12 volt Oil Cooler Mailhot 3-Stage Hydraulic Dump Cylinder Double Acting Rear Door Hydraulic Cylinder with Safety Counter Balance Valve (Valve has to be Hydraulically Actuated for Door to Move). Hydraulic Hose and fittings as required
Y:\General Info-VTC\EQUIPMENT IN STOCK\STOCK\CUSTOM VAC\CV16 COMBO\EQ #000000029 - 2014 CV16 Combo -- WS\EQ #000000029-2014 CV16 Combo -- WS.doc
3
Wash System ( Installed on Passenger Side ): Cat 660 Pressure pump (Rated 10 GPM @ 3000 PSI Max) Unloader valve 1-1/2” Y Strainer Two Hydraulic Hose Reels 100’ x 1/2”pressure hose trigger gun, wand, nozzle and quick coupler 100’ x 3/8” steam hose, steam wand, nozzle and quick coupler
Hot Water System: Hot Shot 980,000 BTU/hr Burner,& Diagnostic panel, relief valve temperature gauge 3000 Pro Watt inverter Steam kit Automatic chimney/lid and Shutter vent to open when burner is ignited. Glycol Flush Tank /Air Blown System
Wash Cabinet: Steel Crossover cabinet c/w steel doors, heaters and interior lights Small door in large door for hose access P/S Cabinet Urethane foam insulated
Frame Unit, Decking : 3” x 6” HSS Tubing Full Length Subframe secured to Truck - Transport Canada Code Compliant Sub-Frame supports decking, Rear Hoist Hinges & Front Hoist Cradle Full Length Decking Sheets with Heavy Duty Outrigger Supports & 1-1/4” HSS Steel Tubing Handrails, Close in Plates, Rear Tire Skirt & C/S Hose Stoppers Code Rear Bumper with Platform Step & Rear Dirt Shield
Trim:
Two Steel 60” Deck Tool Box with steel doors Two Steel Rear Skirt Fitting Boxes
Electrical System: Waterproof Main Circuit Control Box – Self Contained Power Supply Sealed Wire Harness c/w Waterproof Junction Boxes L.E.D. lamps (Clearance, Park, Signal) Sealed LED Reverse Lamps Six Work Lights 2- front, 2 off first flat bar ring and 2 at rear Electrical System Shut-Down at Key Sealed Rear Skirt Lamp Modules Stop & Turn L.E.D. Sealed Lamp Modules on Top Ring of Rear Door Back-Up Alarm Deck Mount Blower Control Switch
Y:\General Info-VTC\EQUIPMENT IN STOCK\STOCK\CUSTOM VAC\CV16 COMBO\EQ #000000029 - 2014 CV16 Combo -- WS\EQ #000000029-2014 CV16 Combo -- WS.doc
4
Paint Finish/Liner: Entire Tank & Body of Vacuum System Sandblasted ,primed and painted with Endura Paint Water tank Epoxy lined with Devoe 233 Misc. Options Included: Two Slide Out Style Chain Holders 4 Multi-Pin Placards Mud flaps as required 30lb Fire Extinguisher c/w Mounting Bracket & Cover Diesel Flush Tank Assembly 50’ Retractable ground cable
Installation: Complete system installed on Western Star Tri-Drive