800.336.4369
Select Page

Custom Vac CV16 CUBE Combo EQ#000000029

SKU: EQ#000000029 Category:

We are pleased to quote on 2014 Custom Vac CV16 Cube Combination Vacuum/Wash System, EQ# 000000029, with the following specifications:

QUANTITY One

DESIGN: Tank designed and constructed in compliance with TC407/412 CSA B620-03

Debris Tank ( 2640 Imp Gal +3% Outage ): 78” Diameter x 12’ Lg 78” x 5/16” Heads 78” x 5/16” Shells  Three reinforcement rings  Three Rollover Bars  Reinforcing pads on all tank attachments  8” Primary internal shutoff, SS float ball and rubber seat /cage assembly with 6” flanged outlet.  6” Heated tank isolation valve, with air control switch at operation  6” Plumbing  6” Composite loop hose c/w vic clamps  Pressure Vessel Hydrotested to 40 PSI  Full Opening Hydraulic Lift Rear Door c/w 6 pinwheel door locks  6” Load Valve , with internal 6” sandpipe D/S  4” Load Valve, P//S  6” Discharge Valve ,– Bottom Center of Rear Door  All rear valves heated and equipped with air/open, spring/close actuators , flipper style switches ,Aluminum Camlocks and Caps  Recessed Stainless Steel Liquid Level Indicator, indicator with grab handle - D/S  6” Cyclone with Clean-Out Door & 2” Brass Heated Drain  3” x 30 PSI pressure relief vent  2” Pressure Relief Valve in lower Vac/Pressure Piping

Y:\General Info-VTC\EQUIPMENT IN STOCK\STOCK\CUSTOM VAC\CV16 COMBO\EQ #000000029 - 2014 CV16 Combo -- WS\EQ #000000029-2014 CV16 Combo -- WS.doc
2
Water Compartment 4 Cubes (880 Imp Gal ):  20” Manway  Stainless Steel Liquid Level Indicator ,indicator with Long Style grab handle P/S  2” Heated Fill Port c/w Riser/Vent Pipe  2”Heated Drain Valve c/w air actuated valve. Switch control at operator station.  2” Heated hard piped supply line, Direct connection through wash cabinet to wash pump  2” Heated Vacuum Changeover Valve & Air Control switch at Operator Station

Robuschi RB DV 85 PD Blower  High Efficiency Tri-Lobe Design  1600 CFM Free Air Rating  27” Hg Maximum Vacuum  Oil Free Operation (Except Sealed Reservoirs)  Blower Clearance & Timing Inspection Prior to Installation by Hibon (Custom Vac) Certified Technicians  6” Four-Way Divertor Valve (Vacuum to Pressure Modes)  6” Double Door Check Valve (To Prevent Blower Back Spin)  16” Dia. x 20 Micron Rating (Washable) Prestage Blower Filter – Hibon Approved Design  High Torque/High Temp Blower Drive Coupling with Flexible Insert  One Exhaust Silencer, One Intake Silence

Power Take-Off System:  8-Bolt Air Shift P.T.O. (Greaseable Shaft Seal)  Air Shift Controls & Hour Meters in Control Box by Driver’s Seat

Hydraulic System ( Linde Closed Loop Design ):  Closed loop hydraulic motor for blower and triplex  Closed loop hydraulic pump for blower and triplex  Single pump for auxiliary functions  Spool type valve bank  Rear deck controls for rear door  Variable Speed Joystick Control for Blower  Wash pump and Hydraulic reel controls are mounted inside wash cabinet  90 Imperial Gallon Hydraulic Oil Reservoir (Cleaned, Purged & Air Tested Prior to Installation) c/w Intank (10 Micron) Filter, Temperature & Level Indicators  Global Hydraulic Vibrator with Flow Control Valve  12 volt Oil Cooler  Mailhot 3-Stage Hydraulic Dump Cylinder  Double Acting Rear Door Hydraulic Cylinder with Safety Counter Balance Valve (Valve has to be Hydraulically Actuated for Door to Move).  Hydraulic Hose and fittings as required

Y:\General Info-VTC\EQUIPMENT IN STOCK\STOCK\CUSTOM VAC\CV16 COMBO\EQ #000000029 - 2014 CV16 Combo -- WS\EQ #000000029-2014 CV16 Combo -- WS.doc
3
Wash System ( Installed on Passenger Side ):  Cat 660 Pressure pump (Rated 10 GPM @ 3000 PSI Max)  Unloader valve  1-1/2” Y Strainer  Two Hydraulic Hose Reels  100’ x 1/2”pressure hose  trigger gun, wand, nozzle and quick coupler  100’ x 3/8” steam hose,  steam wand, nozzle and quick coupler

Hot Water System:  Hot Shot 980,000 BTU/hr Burner,& Diagnostic panel, relief valve temperature gauge  3000 Pro Watt inverter  Steam kit  Automatic chimney/lid and Shutter vent to open when burner is ignited.  Glycol Flush Tank /Air Blown System

Wash Cabinet:  Steel Crossover cabinet c/w steel doors, heaters and interior lights  Small door in large door for hose access P/S  Cabinet Urethane foam insulated

Frame Unit, Decking :  3” x 6” HSS Tubing Full Length Subframe secured to Truck - Transport Canada Code Compliant  Sub-Frame supports decking, Rear Hoist Hinges & Front Hoist Cradle  Full Length Decking Sheets with Heavy Duty Outrigger Supports & 1-1/4” HSS Steel Tubing Handrails, Close in Plates, Rear Tire Skirt & C/S Hose Stoppers  Code Rear Bumper with Platform Step & Rear Dirt Shield

Trim:
 Two Steel 60” Deck Tool Box with steel doors  Two Steel Rear Skirt Fitting Boxes

Electrical System:  Waterproof Main Circuit Control Box – Self Contained Power Supply  Sealed Wire Harness c/w Waterproof Junction Boxes  L.E.D. lamps (Clearance, Park, Signal)  Sealed LED Reverse Lamps  Six Work Lights 2- front, 2 off first flat bar ring and 2 at rear  Electrical System Shut-Down at Key  Sealed Rear Skirt Lamp Modules  Stop & Turn L.E.D. Sealed Lamp Modules on Top Ring of Rear Door  Back-Up Alarm  Deck Mount Blower Control Switch

Y:\General Info-VTC\EQUIPMENT IN STOCK\STOCK\CUSTOM VAC\CV16 COMBO\EQ #000000029 - 2014 CV16 Combo -- WS\EQ #000000029-2014 CV16 Combo -- WS.doc
4

Paint Finish/Liner: Entire Tank & Body of Vacuum System Sandblasted ,primed and painted with Endura Paint Water tank Epoxy lined with Devoe 233 Misc. Options Included:  Two Slide Out Style Chain Holders  4 Multi-Pin Placards  Mud flaps as required  30lb Fire Extinguisher c/w Mounting Bracket & Cover  Diesel Flush Tank Assembly  50’ Retractable ground cable

Installation: Complete system installed on Western Star Tri-Drive

Additional information